Checkline RTM 20D Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Senzory Checkline RTM 20D. Checkline RTM 20D User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 13
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
P RTM 20 D
with
microprocessor
Users Manual
Version 1.3 –
+31 (0)88 0029000 1(12) RTM 20 D - Users Manual BA 7047be
ba7047be.vp - 040216
CHECK
LINE
®
Zobrazit stránku 0
1 2 3 4 5 6 ... 12 13

Shrnutí obsahu

Strany 1 - Users Manual

P RTM 20 DwithmicroprocessorUsers ManualVersion 1.3 –+31 (0)88 0029000 1(12) RTM 20 D - Users Manual BA 7047beba7047be.vp - 040216CHECK•LINE®

Strany 2

6:1:4 UNIT Alternative UnitThe UNIT- button is used to change between normal unit and alternative unit.The alternative unit mode is indicated by a fla

Strany 3 - 1 General

Accept by pressing the ENTER/ZERO- button (for about 2 seconds) until a colon : is lit upon the left side of the display e.g. . That is the indication

Strany 4 - 2 Technical specification

It can be difficult to immediately understand what kind of overload that is due, but it isimportant to reduce the load as soon as the display flashes.

Strany 5 - 3 RTM 20 D Main parts

7 Error CodesThe following error codes can be displayed at start-up or while in use. The error codes isuseful if the unit must be sent away for servic

Strany 7 - 5 Measuring Practice

CONTENTS page1 General 22 Technical Specification 33 The RTM 20 D main parts 44 Function 55 Measuring Practice 65:1 General 65:2 Various types of rope

Strany 8 - 6 Handling

The RTM 20 D is able tocontain up to 10 differentcalibrations.I.e. measurements can bedone on 10 different ropes,“Rope No”, without beingforced to use

Strany 9 - 6:1:2 ZERO

Weight (RTM + Transp. Case) (kg) 11.2Non-Accuracy Max ( ± % of Cal. Cap.) 3333Non-Accuracy Max ( ± % of Max.Cap.) 2222Temperature range ambient (° C)

Strany 10

4 FunctionBy means of the tightening device of the centre support the rope is forced to decline ac-cording to figure 4:1. The angle will always be the

Strany 11

5 Measuring Practice5:1 GeneralMeasurements using the RTM 20 D can be made in two different ways:1. The rope to be measured is loaded to the force X.

Strany 12 - 6:2:3 After Use

5:4 Slack rope to a specified tensionSelect “Rope No”. Install the RTM on the slack rope. Load the rope until the RTMshows approx. 90% of desired end

Strany 13 - ELECTROMATIC

6:1:2 ZEROWhen installed on the competely slack rope, the RTM should indicate zero on the dis-play otherwise you have to zeroize the instrument. When

Komentáře k této Příručce

Žádné komentáře