Checkline TS2P Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Senzory Checkline TS2P. Checkline TS2P User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 15
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
CHECKLINE
®
BY ELECTROMATIC
Tension Sensors
TS2 Series
Operating Manual
TS2PTS2
TS2B TS2H
TS2L
Zobrazit stránku 0
1 2 3 4 5 6 ... 14 15

Shrnutí obsahu

Strany 1 - TS2 Series

CHECK•LINE® BY ELECTROMATIC Tension Sensors TS2 SeriesOperating Manual TS2PTS2TS2B TS2HTS2L

Strany 2 - TABLE OF CONTENTS

– 9 –WARNING: When threading the process material through the rollers, follow the material path symbol on the front of the sensor. If a force is appli

Strany 3 - 1.0 INTRODUCTION

–10 –4.2 GAIN AdjustmentRequirement: ZERO adjustment carried out. 1. Thread the process material through the measuring and guide rollers, followin

Strany 4 - 2.0 AVAILABLE MODELS

– 11 –5.0 SPECIFICATIONS 5.1 General SpecificationsCalibration According to factory procedureAccuracy For 10% to 100% of range: ± 1% Full Scale

Strany 5 - 2.3 TS2H Models

– 12 –6.0 MAINTENANCE AND SERVICEThe tension meter is easy to maintain. Depending on operating time and load, the instrument should be checked accord

Strany 6 - 2.5 T2B Models

7.0 WARRANTYELECTROMATIC Equipment Co., Inc. (ELECTROMATIC) warrants to the original purchaser that this product is of merchantable quality and conr

Strany 7 - 3.0 OPERATING PROCEDURES

ELECTROMATIC E Q U I P M E N T C O., I N C.600 Oakland Ave., Cedarhurst, NY 11516 – USA TEL: 516-295-4300 • FAX: 516-295-4399CHECK•LINE®INSTRU

Strany 8

– 1 – TABLE OF CONTENTS1.0 Introduction ... 02 1.

Strany 9 - ZEROGAIN

– 2 –1.0 INTRODUCTIONThe TS2 Series of universal tension sensor accurately measure the running tension of wires, cables, yarns, bers and similar pro

Strany 10

– 3 –2.0 AVAILABLE MODELS2.1 TS2 ModelsModel TensionRanges [g]*Measuring Head Width [mm]**Factory Calibration MaterialTS2-50 0 - 50 64 PA: 0.12 mm

Strany 11

– 4 –2.2 TS2P Models2.3 TS2H ModelsTS2P Guide Rollers ModelTensionRanges [g]*Measuring Head Width [mm]**FactoryCalibration MaterialTS2P-50 0 - 50

Strany 12 - 5.0 SPECIFICATIONS

– 5 – ModelTensionRanges [g]*Measuring Head Width [mm]**FactoryCalibration MaterialTS2L-50 0 - 50 150 PA: 0.12 mm ØTS2L-100 0 - 100 150 PA: 0.12 mm Ø

Strany 13 - 6.0 MAINTENANCE AND SERVICE

– 6 –3.0 OPERATING PROCEDURES3.1 Mounting ArrangementsTS2 Series sensors can be mounted in different ways: • Mounting by using the frontplate on a

Strany 14 - 7.0 WARRANTY

– 7 –3.3 OptionsCode DC Analog output 0 - 10 V DC Code MA Analog output 4 - 20 mA3.4 Initial Setup• Install the sensor at the desired measuring

Strany 15 - ELECTROMATIC

– 8 –4.0 INTERNAL ADJUSTMENT OF THE SENSORSIf the sensor has been delivered with a display unit, the ZERO and GAIN adjustments should only be carried

Příbuzné modely TS2B | TS2L | TS2H | TS2 |

Komentáře k této Příručce

Žádné komentáře