NOTES
Electromatic Equipment Co., Inc.
-1-
TABLE OF CONTENTS
1.0 Positioning the instrument ……………………………………………. 2
2.0 Calibration curves …………………………………………………….. 2
3.0 Description of definitons ……………………………………………… 3
4.0 Application range ……………………………………………………… 4
5.0 Design of the device ………………………………………………….. 4
6.0 Menu level overview ………………………………………………….. 5
7.0 Operating the instrument …………………………………………….. 6
8.0 Transfer saved data to the PC ………………………………………. 7
9.0 Print saved data ………………………………………………………. 8
10.0 Single-point adjustment with 50% humidity standard …………….. 9
11.0 Offset adjustment ……………………………………………………… 11
12.0 Reset to factory calibration …………………………………………… 12
13.0 Conditioning of the sensor ……………………………………………. 12
14.0 Care instructions ………………………………………………………. 13
15.0 Changing the batteries ……………………………………………….. 13
16.0 Exemprion from liability ………………………………………………. 14
17.0 Optional accessories …………………………………………………. 14
18.0 Technical data ……………………………………………………….... 15
19.0 Common reasons for incorrect measurements ……………………. 16
20.0 Warranty ……………………………………………………………….. 17
Zobrazit stránku 0
1 2 3 4 5 6 ... 10 11

Shrnutí obsahu

Strany 1

 Electromatic Equipment Co., Inc. -20- NOTES  Electromatic Equipment Co., Inc. -1- TABLE OF CONTENTS 1.0 Positioning the instrument …………………

Strany 2

 Electromatic Equipment Co., Inc. -10- 5. Now put the third gasket ring into the bottom part. 6. Fit the metal ring on the third gasket. 7. Tak

Strany 3

RH6 PAPER MOISTURE METER OPERATING INSTRUCTIONS

Strany 4

 Electromatic Equipment Co., Inc. -2- 1.0 POSITIONING THE INSTRUMENT Insert the sword-sensor into the stack for only approx. 10 cm, and

Strany 5

 Electromatic Equipment Co., Inc. -18- NOTES  Electromatic Equipment Co., Inc. -3- 3.0 DESCRIPTION OF DEFINITIONS Relative air humidity: in

Strany 6

 Electromatic Equipment Co., Inc. -4- 4.0 APPLICATION RANGE Within the normal application range (normal range) the accuracy of the device is as i

Strany 7

 Electromatic Equipment Co., Inc. -16- 19.0 COMMON REASONS FOR INCORRECT MEASUREMENTS • Sunlight or other sources of heat or cold that

Strany 8

 Electromatic Equipment Co., Inc. -6- 7.0 OPERATING THE INSTRUMENT Switching on: Press for 3 seconds. Changing the calibration curve: or .

Strany 9

 Electromatic Equipment Co., Inc. -14- 16.0 EXEMPTION FROM LIABILITY For miss-readings and wrong measurements and of this resulting damage we ref

Strany 10

 Electromatic Equipment Co., Inc. -8- 9.0 PRINT SAVED DATA To print your saved data, connect the device to the printer using the printer cable

Strany 11 - PAPER MOISTURE METER

 Electromatic Equipment Co., Inc. -12- 12.0 RESET TO FACTORY CALIBRATION 1. Press the button two times to reach the menu point Options. 2.